Maker of katana microtome, a device that turns a normal SEM to a Volume SEM for serial block-face imaging. #SBEM #SBFSEM #volumeEM #3DEM #SEM

Oxford
Joined September 2019
Photo by ConnectomX (@connectomx3d)Photo by ConnectomX (@connectomx3d)Photo by ConnectomX (@connectomx3d)Photo by ConnectomX (@connectomx3d)Photo by ConnectomX (@connectomx3d)Photo by ConnectomX (@connectomx3d)Photo by ConnectomX (@connectomx3d)Photo by ConnectomX (@connectomx3d)Photo by ConnectomX (@connectomx3d)Photo by ConnectomX (@connectomx3d)
Excited to announce the installation of the first katana microtome @america @WashU , housed in Professor Eduardo Rosa-Molinar’s incredible superlab! We’re absolutely blown away by the cutting-edge instruments available here—it’s a playground for innovation. The introdution of katana microtome opens up a world of possibilities of integrate it with various imaging techniques to create a plethora of corrective imaging workflows that could redefine #volumeEM and #SBFSEM. A huge thank you to the brilliant engineers from @Hitachi_EM for their support in integrating the katana with the SU7000. That microscope is an absolute powerhouse with its large chamber size and abundance of available ports. We’re thrilled to see how this setup will push the boundaries of what we can achieve.
2
11
562
Segmentation tools have mostly learned on 2D images and then get applied to volumes one slice at a time, with stitching afterwards. A new bioRxiv preprint from Constantin Pape's group in Göttingen, with collaborators in Würzburg, Singapore and Sydney, tries a different route with μSAM2. The trick is borrowed from video. SAM2 was built to follow an object through the frames of a movie, so the authors treat the z axis of a stack as time. You click once on an object in one slice, and the mask is propagated up and down through the volume. For automatic segmentation they added a decoder that stacks the per-slice embeddings and runs 3D convolutions over them, so neighbouring slices share information, and it predicts foreground, boundaries and distances to object centres for a watershed or for generating prompts. The training set is large. On the EM side it has about 1.6 million annotated cellular structures from ssTEM, ssSEM, FIB-SEM, SBF-SEM, multi-beam SEM and tomography, including proofread segmentations from big connectomics projects. There are also two separate EM models, one trained on 155,137 mitochondria and one on 31,088 nuclei. They kept them apart because the nucleus data has unlabelled mitochondria and vice versa. The organelle numbers are the part I'd look at first. Scoring uses mean segmentation accuracy averaged over IoU thresholds from 0.5 to 0.95, which is harsh. On in-domain 3D data the mitochondria model reached 0.568 against 0.405 for MitoNet, and the nucleus model 0.706 against 0.261 for NucleoNet. On unseen datasets nuclei held up at 0.602, while mitochondria fell to 0.240, still ahead of MitoNet's 0.171. Mitochondria in a new dataset are still hard. There is also a real SBF-SEM test: an HCT116 colorectal cancer organoid, heavy-metal stained, imaged on a JEOL SEM fitted with our Katana microtome at 4 kV, 16.6 nm pixels and 100 nm sections, 950 sections per volume. Nuclei came out mostly right, with a few missed where signal-to-noise was low or there were imaging artefacts. The authors are open about limits. Fine-tuning still needs powerful hardware and takes dozens of minutes to hours. A single model for mitochondria, nuclei, ER, Golgi and the rest isn't possible yet because the annotated data doesn't exist. My own question is about anisotropy. Treating z as time assumes each slice looks like the one before it. At 16.6 nm in plane and 100 nm in z, that holds for a nucleus but much less for a thin mitochondrion or a fine process. How well propagation handles thick sections compared with near-isotropic FIB-SEM would be worth measuring directly. And the missing ER and Golgi labels look like something shared annotation work across labs could fix. Archit, Teuber, Griebel ... Huisken & Pape. Segment Anything for Microscopy 2. bioRxiv, posted 17 Nov 2026. doi.org/10.64898/2026.11.12.… #volumeEM
1
142
On mouse pancreatic beta cells, nnU-Net with a boundary channel scored 92.8% on voxels and 16.9% on separating individual mitochondria. That gap is the most useful thing in MitoEM 2.0, a new benchmark from Peng Liu, Donglai Wei and colleagues, with Kedar Narayan and Ignacio Arganda-Carreras, published in Scientific Data this week. The authors argue that existing mitochondria benchmarks are too easy. Mitochondria in those sets sit apart and have simple shapes. Real tissue has packed mitochondria, hyperfused networks and thin necks a few voxels wide. So they built a harder set from published volume EM data. They did no new imaging. The set has eight subsets across human, mouse and Drosophila, three modalities and more than 8,000 mitochondria in 28 volumes. Voxel sizes run from 8 x 8 x 30 nm to 16 x 16 x 16 nm. The SBF-SEM subset is mouse brainstem. It has three volumes of 1000 x 1000 x 100 voxels at 8 x 8 x 30 nm and 2,058 mitochondria, the largest count in the set. The authors note charging-related intensity steps and say the main failure there is missed instances at borderline contrast. Labels started as an nnU-Net draft with a boundary channel. People then proofread every volume slice by slice. A second annotator redid eight volumes independently, and the agreement was F1 0.93, range 0.90 to 0.96. The part I like is how they measure difficulty. The Dilation Collision Index grows each labelled mitochondrion by one voxel and counts the neighbours it touches. That predicts false merges. The Erosion Fragility Index shrinks it by one voxel and counts the extra pieces. That predicts false splits. Older benchmarks cluster low on both scores. This set does not. The baselines show the gap. Averaged over the eight subsets, the same nnU-Net reached 87.0% voxel accuracy and 32.0% instance accuracy at IoU 0.5. The best instance score came from fine-tuned MitoNet, at 44.7%. On cerebellar mossy fibre boutons, the most crowded subset, nnU-Net scored 83.4% on voxels and 6.6% on instances. Where voxel scores are similar and instance scores differ, the authors blame the decoding step that turns pixel predictions into separate objects. There are limits. Five subsets have one volume each for training, validation and test. The baselines ran with default settings. The authors also say both indices depend on voxel size and ignore image problems such as charging and staining. Our angle: at 30 nm sections, the mossy fibre failure is over-merging across necks that span only one or two sections. Some segmentation difficulty is fixed when the block is cut. These two indices would let someone test that by imaging the same tissue at different z-steps. Liu P, Shen B, Liu L, Wang Q, Zhang S, Bhardwaj A, Arganda-Carreras I, Narayan K, Wei D. MitoEM 2.0: A Benchmark for Challenging 3D Mitochondria Instance Segmentation from EM Images. Scientific Data 13, 1647, published 19 Nov 2026. doi.org/10.1038/s41597-026-0… #VolumeEM
89
Cryptosporidium, a leading cause of diarrhoeal disease in young children, lives just under the surface of a gut epithelial cell, behind a convoluted membrane called the feeder organelle. How that membrane gets built has been argued over for decades. A paper published in PLOS Biology on 11 November 2026 from Boris Striepen's lab at Penn with the Robert Koch Institute makes a simple claim. The parasite uses one organelle twice. Its single rhoptry breaks into the host cell, and that same membrane later becomes the feeder. They tagged a dense granule protein with fluorescent reporters and caught 27 invasion events live. Granules move about 1.5 µm to the parasite apex at 100 to 200 nm per second. Trafficking took 16 s on average, secretion 36 s, and the whole invasion around 5 min. Host actin assembles at the contact site within 5 s, before the granules move, so rhoptry discharge comes first and granule secretion happens before the parasite is internalised. That order is the reverse of Toxoplasma and Plasmodium, where dense granules fire only after the parasite is inside its vacuole. The 3D work pinned the structure down. Infected mouse intestine, heavy-metal stained in the block, was imaged by SBF-SEM on a Teneo VolumeScope at 2 kV and 100 pA, 4 nm pixels over a 10,240 by 10,240 frame, 40 nm sections. Stacks were registered, denoised and segmented by hand. An invading parasite could be followed in its entirety, and a single rounded apical compartment appeared near its tip. Electron tomography of 150 nm sections then resolved a membrane around that compartment, granules docked to it, and a conduit from its lumen through the conoid into the host cytosol above a dense band. Two tagged rhoptry membrane proteins, CpARO and CpRON11, decorated the rim of that compartment, and its diameter agreed across methods, 0.62 µm by expansion microscopy, 0.72 µm by TEM, 0.70 and 0.66 µm with the two markers. Hours later those markers flattened into a line at the host-parasite boundary together with the glucose transporter CpGT1, which is the feeder. The authors state the limits. Everything is chemically fixed, so cryo-fixation is the obvious next test. What triggers granules to fuse with the empty rhoptry is unknown, and whether the conduit is leftover rhoptry machinery or built during invasion is open. Our own reading is about the method mix. At 40 nm sections, SBF-SEM is coarse against a 0.65 µm compartment, so it was not carrying the resolution here. It was carrying completeness, one whole parasite in real gut tissue, enough to say there is one compartment and where it sits. Tomography supplied the membranes. A lot of block-face work is like this, a counting and context argument rather than a resolution argument, and it pays to know which job a volume is doing before picking section thickness. Cohen A, Bergner T, Guérin A, Lebrun M, Laue M, Klotz C, Striepen B. The single Cryptosporidium rhoptry sequentially drives invasion and host-parasite interface formation. PLOS Biology, 11 November 2026. doi.org/10.1371/journal.pbio… #volumeEM
102
Most connectomics runs on ultrathin material. Layers of roughly 8 to 50 nm are imaged at 4 to 8 nm pixels, because that is what lets a big volume finish in reasonable time. The price is that small or faint structures are hard to call at that resolution. Gap junctions are the obvious example. A brief communication out today in Nature Methods, from Wei-Chung Allen Lee's lab at Harvard Medical School and Mark Ellisman's group at NCMIR in San Diego, goes the other way. Cut thick, 500 to 1000 nm, and recover depth inside each section with electron tomography. Tomography is usually slow. Their full-quality reference uses four tilt axes with 241 tilts each over ±60°. So the question is how few tilts still let you trace neurons and see synapses. They used mouse cerebellar cortex, heavy-metal stained and resin embedded, cut on an ultramicrotome onto slot grids. Imaging was on a 300 kV Titan Halo with an 8k DE-64 direct detector at 3,300x or 11,000x, with binned pixels of 4.91 nm and 1.44 nm. They took dense tilt series, rebuilt the same areas from subsets of 5 to 121 tilts, and scored each against the reference with Fourier shell correlation. The working point was 21 tilts over ±30°. Axons, chemical synapses, gap junctions and spinule-like protrusions between glia and neurons were still identifiable. At 3,300x the FSC resolution was 11.8 nm for 500 nm sections, 12.7 nm for 750 nm and 14.8 nm for 1000 nm. At 11,000x it reached 4.2 to 4.6 nm. That is about 50 times fewer images than full tomography, on sections about 20 times thicker than usual. Tilting beyond ±20° to ±30° added little for thick sections. As a volume test they stitched fifteen 600 nm sections into a block of about 10 by 10 by 9 µm. A parallel fibre axon synapsing onto two Purkinje cell spines stays continuous through every section, with material lost at section boundaries estimated at under 10 nm. They then went back to the same spots at 11,000x. The limits are real. FSC here is a relative yardstick, not true resolving power, and resolution is worse in z than in plane. The demo block is around 900 µm³, far from connectome scale. Scaling needs automated handling of tens of thousands of thick sections, and 300 kV microscopes are not common. My own take is the contrast with block-face imaging. SBF-SEM gets its z resolution by cutting thin and discarding each layer, which makes it easy to automate and means you can never go back. This makes the opposite trade. Cut thick, keep everything, pay in tilts. A fast low-magnification pass could find the contacts worth a closer look, with high-magnification tomography only there. Figures are from the open preprint. The journal version adds machine-learning image augmentation, which I haven't read in full. Kuan, Phan et al. and Lee. Scalable electron tomography for connectomics. Nature Methods, 2026. doi.org/10.1038/s41592-026-0… Preprint: pmc.ncbi.nlm.nih.gov/article… #connectomics
1
230
Most volume EM samples go through aldehyde fixation, osmium, heavy metal stain, dehydration and resin before anyone images them. A new bioRxiv preprint from the Danforth Center and Stanford skips all of that and images whole cyanobacteria frozen in their own water. The organism is the filamentous cyanobacterium Anabaena. The team stuck filaments to gold grids coated with poly-L-lysine, because on plain grids blotting stripped most filaments off. Then they plunge-froze them in liquid ethane and found target cells inside the ice by their own chlorophyll and phycobilisome autofluorescence. Cells were then capped with platinum, trenched with xenon, and milled slice by slice with an argon plasma beam on a Thermo Fisher Helios 5 Hydra cryo-pFIB-SEM, imaging each fresh block face at 1.2 kV. They imaged two whole cells, one per species. A. inaequalis took 695 slices at 3 x 3 x 6 nm voxels. Anabaena sp. UTEX 2576 took 1,312 slices at 4 nm isotropic voxels. They aligned the stacks with SIFT in Fiji and segmented them in Dragonfly. Cell wall, carboxysomes and cyanophycin were traced by hand. Thylakoids and polyphosphate granules went to a 2.5D U-Net trained on 4 to 5 annotated frames. Because the whole cell is in the volume, every inclusion can be counted and expressed as a fraction of the cell. The UTEX cell (40.2 µm³) had 8 carboxysomes averaging 67.9 x 10^6 nm³. The A. inaequalis cell (25.3 µm³) had 16, smaller and more uniform at 19.2 x 10^6 nm³. Yet carboxysomes took up almost the same share of each cell: 1.35% and 1.21%. Cyanophycin storage differed about 7-fold, 0.03% versus 0.21%, mostly down to one large granule. The number I keep coming back to is thylakoid spacing. Vitrified, the gap between neighbouring thylakoid pairs measured 76.2 ± 3.7 nm. Freeze-substituted, resin-embedded cyanobacteria in earlier work gave 30 to 50 nm (Synechocystis) and 50 to 60 nm (Cyanothece). Phycobilisomes stick out about 32 nm from each membrane, so two facing layers need at least 64 nm. The authors suggest dehydration and resin shrinkage may be squeezing that space in conventional prep, while noting that species could also differ. The authors are open about the limits. It is n = 1 cell per species, so this is a demonstration, not population data. The thylakoid numbers come from 5 and 4 measurements. Carboxysome shells and septal junctions weren't resolved, and the U-Net could not separate phycobilisomes from the membrane they sit on. Charging of the unstained frozen sample still limits image quality. For anyone doing room-temperature SBF-SEM or array tomography, I think this is a useful ruler. Our stained, resin-embedded blocks are great for tracing and counting, but spacings inside membrane-dense compartments are measurements of the processed specimen. A few cryo reference cells like these give you something to calibrate against. The volumes are public too, EMPIAR-14092 and 14093. Angermeier, Rotkina, Lebow, Chiu, Burch-Smith & Czymmek, bioRxiv, posted 4 Nov 2026. doi.org/10.64898/2026.11.02.… #VolumeEM
1
110
A fruit fly has no blood vessels in its brain. Oxygen arrives through air tubes. A new preprint traces every one of them in a single adult brain, and they don't join up. Insects breathe through a tracheal system, gas-filled tubes that run in from spiracles on the body. In the adult fly brain the finest branches, the tracheoles, are under 1 µm across. That is too thin for ordinary fluorescence imaging, and the usual genetic reporters fade in adults. So nobody had a full map. Cho, Ng, Schoenberg and colleagues at Mount Holyoke College used FAFB, the open serial-section EM volume of a 7-day-old female fly brain that also underlies the FlyWire connectome. Tracers placed skeleton nodes at the centre of every tracheole lumen in CATMAID, and expert reviewers checked each one. To test completeness, two people went through every 250th section of the whole brain and confirmed each lumen had a node. The skeletons were then matched to FlyWire's automatic segmentation. That segmentation had often glued glia and neuron fragments onto the tubes, so those were split off by hand. The result is 117 tracheoles with 12.98 cm of total length. The same brain holds 149.2 m of neuronal path. They end in 1,376 blind tips inside the tissue and never form a connected network like our capillaries do. Most enter through the optic lobes (63 of 116 entry points), and none enter the central complex. One tracheole sits entirely inside the brain with no entry point at all. Coverage is tight. 59.3% of points on the network are within 10 µm of a different tracheole, and 91.8% within 20 µm. Volume fraction runs from 0.028% in the lateral horn to 0.14% in the central complex. Left and right hemispheres get the same amount, but the branches are not mirror images. Even after registering each neuropil pair, only about a third of points had a partner within 5 µm on the other side. Then the synapses. Across 78.3 million presynaptic sites, the median distance to a tracheole was 7.87 µm, and 97.3% were within 20 µm. But compared with non-synaptic stretches of the same neuron, synapses sat slightly farther away, a median 0.36 µm, and only within about 15 µm of a tube. The authors suggest mitochondria along the axon may set where oxygen is used, and glia hugging the tubes may keep synapses back. Limits: one brain, one sex. The air sacs were removed in dissection, so origins outside the brain are inferred. The 386 odd membrane pinches they call tracheole link connectors, and the isolated tracheole, could be fixation artifacts. Glia aren't segmented in FAFB, so that idea can't be tested here yet. What I like is the reuse. A volume imaged for neurons held a second organ system that the segmentation treated as clutter. The every-250th-section audit is a cheap completeness check anyone tracing a sparse structure in their own volume could copy. Cho H, et al. A complete adult Drosophila melanogaster brain tracheolar network. bioRxiv 2026. doi.org/10.64898/2026.11.09.… #vEM #connectomics
1
419
How many axons are hiding in an OCT scan? A new monkey glaucoma study used serial block-face SEM to count them. Clinics track glaucoma by measuring retinal nerve fibre layer (RNFL) thickness around the optic disc with OCT. But a micron of RNFL does not hold the same number of axons everywhere. Axon size changes around the disc, and glia and blood vessels take up space too. Kharal, Sullivan and Patel at the University of Houston set out to measure both, then turn OCT thickness into an axon count. They induced glaucoma in one eye of 22 rhesus monkeys with laser scarring of the drainage angle and followed them with OCT. In five animals they cut roughly 0.75 x 0.75 mm pieces of retina from six spots around the optic disc, in both eyes, and gave them a heavy-metal stain (osmium, thiocarbohydrazide, uranyl, lead). The blocks went into a Tescan MIRA3 SEM with a Gatan 3View 2. They sectioned to about halfway through the tissue, roughly where the OCT scan path sits, and took a single 8192 x 8192 backscatter image of the block face at 9.2 to 30.5 nm per pixel and 7 to 12 kV. They traced 431,768 axons by hand. Mean axon area was 0.46 µm² in control eyes and 0.43 µm² in glaucoma eyes, with no significant difference. Location mattered more. Temporal axons were the smallest (0.28 µm² in controls) and superior nasal axons the largest (0.66 µm²). The non-axonal part was the surprise. As a share of the layer it rose from 28% in controls to 45% in glaucoma eyes. In absolute area it barely moved (1592 vs 1441 µm² in a 60 µm strip). The disease takes away axons and leaves the glia and vessels behind. The OCT data agree. Plotting RNFL thickness against optic nerve axon counts, the line hits zero axons at 31.4 µm of thickness, about 28% of a normal layer. The slope works out to an average axon of 0.43 µm², matching the histology. A six-sector model built on the EM numbers predicted total optic nerve axon counts with a slope of 0.99 and a bias of about 9,500 axons, against counts of around 1.44 million in healthy eyes. So a thin RNFL is not all lost axons. There is a floor of other tissue, and it differs by region. The authors expect a location-aware model to tie OCT more closely to visual field loss. The authors list the limits. Only five animals went through EM, the laser model progresses faster than human glaucoma, the images can't split astrocytes from microglia and capillaries, and the continuous model has no independent validation set yet. What strikes us is that they ran an SBF-SEM mostly for single faces. One check went deeper. They imaged three depths about 10 µm apart, 94,155 axons in all, and mean size stayed put (0.39, 0.39, 0.38 µm²). A full serial stack of the same blocks could separate the glia from the vessels, follow axons through the layer and remove the oblique-cut images they had to drop (6 of 60). Kharal A, Sullivan M, Patel NB. Axon Content of the Circumpapillary Nerve Fiber Layer in Experimental Glaucoma. IOVS 2026;67(13):8. doi.org/10.1167/iovs.67.13.8 #VolumeEM
142
Every big connectome ends with the same chore. The segmentation has glued two neurons together, a proofreader clicks near the bad join, and the software has to decide where to cut. A new arXiv preprint from Notre Dame and Korea University looks hard at that step. Byunghyun Ko, Won-Ki Jeong and Chaoli Wang call their method ContactCut. Their point is that a click doesn't define the split on its own. The segmentation is stored as a graph of supervoxels, and every place where two supervoxels share voxel faces is a contact. Within 500 nm of the click there are usually several contacts that could act as the two seeds for a min-cut, and each gives a different split of the whole object, even with the same solver. So instead of seeding at the nearest contact, ContactCut tries every nearby contact, runs a seeded minimum cut on the full graph for each one, and scores the resulting partitions. The scoring looks only at structure, never at the EM images. It prefers splits where both sides stay in one connected piece, where the smaller side isn't a tiny crumb, and where the cut runs through a narrow connection. A ranker with two learned weights balances the last two. A second mode tries pairs of contacts and offers a proofreader five alternatives. They tested it on real edits that proofreaders made in MICrONS minnie65 (mouse visual cortex) and FlyWire (adult fly brain). On 733 MICrONS test edits the main score was 0.657, against 0.598 for the best graph-based method and 0.532 for the best learned one. On 2,929 FlyWire edits it scored 0.641, against 0.608 and 0.541. A ranker trained only on MICrONS scored 0.6405 on FlyWire, almost the same as 0.6414 when trained on FlyWire itself. It runs on a CPU, with a median of 0.30 s per edit on MICrONS and 0.11 s on FlyWire. It matters because false merges are the expensive error. One wrong fusion corrupts the shape and wiring of several neurons. There are limits. The reference is the edit people actually made, so this measures agreement with past proofreading, not verified neuron identity. It only handles two-way splits. A score around 0.65 still leaves plenty for a human to check, and the best single-contact cut available scores 0.843 on MICrONS, so the ranker doesn't yet find the best option every time. It's also a preprint, not yet peer reviewed. The part I like most is that it ignores the images completely. It works on the shape of the supervoxel graph alone, which is probably why a model trained on mouse cortex carries over to the fly brain with almost no loss. The flip side is that the fix can only be as good as the supervoxels. If a section is damaged or misaligned there may be no clean contact to cut through. Clean, evenly cut volumes at acquisition still save time later. Ref: Ko, Jeong and Wang (2026), "ContactCut: A Partition-Aware Contact Selection Framework for False-Merge Correction in Connectomics", arXiv:2611.01457. arxiv.org/abs/2611.01457 Code: github.com/bentake/ContactCu… #connectomics
🤖 Made with AI
2
112
Vimentin filaments move through the cell along microtubules, and they need kinesin-1 and dynein to do it. Yet a 3D FIB-SEM study from the Gelfand and Lippincott-Schwartz labs found the filaments sit on average 233 nm from the nearest microtubule, and over 85% of microtubule length is more than 50 nm from any vimentin filament. So how does a filament use a track it barely touches? A new bioRxiv preprint from the same groups at Northwestern and Janelia tests a simple idea. The filaments hitchhike on mitochondria, which already carry the motors. The volume EM work reuses an existing dataset. They went back to a FIB-SEM volume of the perinuclear region of a COS-7 cell, acquired at 2 nm isotropic sampling by Janelia's CellMap team, in which 572 vimentin filaments and 39 microtubules had already been traced by hand. They added the surfaces of 15 mitochondrial profiles from an 8 nm segmentation, modelled the filaments as tubes of 6 nm and 12 nm radius, and measured the gaps in both directions. In that volume, 4.61% of the mitochondrial surface lay within 50 nm of a vimentin filament, against 1.15% within 50 nm of a microtubule. Single filaments curve along a mitochondrion at sites that only partly overlap with where microtubules touch it. The two are not simply stuck to the same track. The causal tests are light microscopy. Knocking down TRAK1, the adaptor that links mitochondria to kinesin-1, moved mitochondria toward the nucleus in RPE cells, with mean radial position falling from 0.52 to 0.40. Vimentin moved with them, from 0.56 to 0.40, and its peripheral fraction fell from 36.0% to 13.5%. Microtubules stayed spread out. Then, in cells with no kinesin-1, they tethered a tail-less kinesin motor to the mitochondrial outer membrane. That motor can't bind vimentin. Mitochondria moved outward, 0.34 to 0.60, and vimentin followed, 0.34 to 0.51. Pulling mitochondria inward with a plant minus-end motor did the reverse. Hitchhiking is already known for peroxisomes, lipid droplets, ER and RNA granules. This adds a cytoskeletal filament to that list. The authors are open about the limits. The EM is one cell, one volume and 15 mitochondrial profiles, and the contact fractions are small. Not all vimentin follows. When mitochondria were dragged inward, part of the peripheral network stayed put, so they propose a hybrid model with other routes as well. The physical linker, plectin 1b or the vimentin head domain, is still open. What I like here is that the puzzle itself came from volume EM. Light microscopy can't measure a 50 nm gap. A well-traced 3D volume showed the paradox, and the same volume, reopened with a new question, pointed at the vehicle. Ref: Renganathan, Moore, Adam, Lippincott-Schwartz, Gelfand. Mitochondria-coupled hitchhiking drives vimentin intermediate filament transport. bioRxiv, posted 4 Nov 2026. doi.org/10.64898/2026.11.02.… #VolumeEM
🤖 Made with AI
67
How much gold a cell takes up is only part of the story. Where it ends up matters too. Bottone and colleagues used serial block-face SEM to measure both inside a tumour spheroid. They exposed FaDu cells to citrate-capped gold nanoparticles, 50 nm in diameter, before and during spheroid formation. They fixed the spheroids with glutaraldehyde, applied reduced osmium, thiocarbohydrazide and osmium staining, then uranyl acetate and lead aspartate, and embedded them in Epon-Araldite resin. A Thermo Fisher Apreo Volumescope imaged a region near the centre of one spheroid. Acquisition used 10 × 10 × 50 nm voxels, 1177.33 V, 100 pA and a 0.5 µs dwell time. After denoising and registration, the volume measured 100.00 × 100.65 × 35.05 µm. The dataset contained 124 cells and 83 nuclei, including objects cut by its boundaries. The analysis used separate tools for different targets. Fine-tuned Cellpose-SAM models segmented cells and nuclei. An empirical Bayes method separated bright nanoparticle signal from background, with a 95% probability threshold. They estimated particle counts from cluster volumes, assuming close-packed 50 nm spheres. These are estimates, not individually resolved particle counts. Gold clustered near nuclei. The median particle-voxel distance from the nuclear surface was 2.57 µm, with the middle half between 1.17 and 3.78 µm. They detected no particles inside nuclei. Across 18 cells fully inside the volume, estimated median gold uptake was 0.042 ng per cell, but uptake varied over several orders of magnitude. The same segmentation let them measure cell and nuclear shape in 3D, including local ridges and indentations that a single section cannot describe. They also released the images, annotations, code and model weights. For nanomedicine, this connects dose with location. The authors discuss radioenhancement, where damage depends on how close particles sit to biological targets. Bulk elemental measurements cannot show that spatial relationship. This study did not test therapeutic efficacy. The limits matter. This was one imaged spheroid, without biological replication. The slice spacing could not reliably resolve isolated particles or tiny aggregates, which the analysis excluded. Touching clusters could merge during segmentation. Cellpose-SAM also struggled on images unlike its training data. My takeaway is that the acquisition resolution helps define what counts as uptake. Here, the spatial map describes detectable aggregates, not every gold particle. Comparing delivery strategies will need that detection limit alongside the uptake number. Bottone et al., Small, 2026. doi.org/10.1002/smll.75947 Image: Bottone et al., bioRxiv, Fig. 3, CC BY 4.0. doi.org/10.64898/2026.04.17.…
156
We're getting some fantastic #SBFSEM results analysing this wheat sample using our latest precision charge neutralisation and our kensho backscattered electron (BSE) detector at 150 ns dwell time with 3 nm pixel size.. The clarity of the image is too good not to share. In #volumeEM, analysing challenging, non-conductive biological samples like wheat can be tricky, but the combination of the precision charge neutralisation and kensho detector help us to obtain images without charging artifacts completely.
75
Transform your SEM to a #volumeEM today with katana microtome.
1
1
276
Greetings from M&M 2025! 🔬 We have arrived in beautiful Salt Lake City and begun for a great week of Microscopy & Microanalysis. The star of our booth is our katana microtome, and we're showing it off with live demos! Swing by Booth #1622 to watch it in action. A big thanks to our partners in the US, Angstrom Scientific, for having us on the booth! #MM2025 #volumeEM #vEM #SEM #SBFSEM #serialblockface #microtomy
84
We are officially set up and ready to go at the Microscience Microscopy Congress 2025 #MMC2025! 🎉 Come and visit the ConnectomX team at booth 143 next to the food hall to see our revolutionary katana microtome in action. We're running live demos showing how you can transform any SEM into a powerful high-resolution, Volume SEM. Whether your focus is neuroscience, cell biology, or materials science, we're excited to show you what's possible. We look forward to seeing you there!
1
116
Just completed our first katana microtome installation and training in LATAM at the Brazilian Nanotechnology National Laboratory (LNNano)! Seamlessly integrated with a FEI Quanta 650, now ready for high-throughput #volumeEM and #SBFSEM. Huge thanks to Rodrigo and his team for the warm hospitality and collaboration! 🇧🇷🔬
1
1
113
@grok can you translate this post to Portuguese?
1
71
Bergen? Happy to report that we're in right place for SCANDEM 2025, to give a talk on serial block-face SEM, and the kinds of multimodal and correlative workflows we are now able to achieve. Please pop by to the Spectral AB booth (you can't miss it) to have a chat about the ConnectomX katana in-situ microtome, and hopefully Joe will see you in Room C, 13:00 - 13:30! A big thanks to Spectral for their organisation and invitation to the event. #vEM #SBFSEM #EDS #EBSD #SEM
2
86
It's been a busy May! We've been privileged enough to take the katana microtome on tour this past month, giving two presentations on Serial Block-Face SEM (SBF-SEM) at conferences in the U.S. and Poland, visiting labs and showing it's capabilities to the ever-growing volume EM community. 🧵 #SBFSEM #vEM #ElectronMicroscopy #3DImaging #FIBSEM #Histochemistry #Microscopy #CLEM #MultiModal #EDS #EDX
1
93
📍Then off to the '56th Symposium of the Polish Society of Histochemists and Cytochemists' near Olsztyn, made possible by our partners at PIK Instruments Sp z.o.o.. A great discussion sparked on future of volume data processing and analysis, and always a pleasure showcasing the instrument in action at the booth.
1
60
📍Next up: SCANDEM2025 in Bergen, Norway next week, with our partners at Spectral AB. If you are attending, please drop by the booth to say hello, and pencil in Thursday 12 June at 13:00-13:30 to hear about the advances we are making in multimodal (including EDS/EBSD) and correlative workflows with SBF-SEM. Thanks for reading!
62