Recent projects (ongoing or finished); pretty much all of them are done by myself from concept to execution:
* VR headset with integrated computer (SimulaVR), pretty much doing all the hardware (high-speed PCB design, FPGA gateware, general product engineering, etc.) and a good chunk of the software there. Only project that has employees working on it. -- ongoing
* SiC membrane ultrafiltration for swimming pools (fully automated manual/chemical backwash, chemical dosing, data logging, etc.) -- finished
* Fluidized bed coffee roaster -- prototype works, but unfinished (needs some fixes and an enclosure)
* VFD controlled electrical pressure washer (~11 kW) -- finished
* Automated water treatment system for aquaculture -- functional, but unfinished
* DC microgrid for grid-parallel and off-grid use with seamless switchover -- ongoing, currently designing the battery storage system
* Silent, water-cooled workstations for CAE or LLM use with all expansion cards connected via MCIO cables -- functional, but needs a custom enclosure design and some power distribution PCBs done
I used to do software and considered a PhD in programming language theory (Haskell dependent type stuff) back in the day, but I don't code as much nowadays.
1
2
685
The controls for my pond's water treatment.
Rittal's RiLineX is super cool. The best busbar system I've encountered yet for industrial controls and great for maintenance (need to swap a MCB? remove the carrier, swap it, slide it back in all without turning it off)
Also a nice excuse to try out the G220. G210 hasn't released yet when I built this, so it's a bit overkill, but a very nice VFD regardless.
255
In short, if you want to prevent being account flagged:
* Do not post primarily NSFW (I'm gonna take ~1 in 5 posts as a guideline for myself)
* Do not post more than 1 NSFW post every 26 hours (the user label trigger at 3 or more)
* If you post more than 2 images that a model *might* detect as NSFW, check on a logged out account whether those images were flagged as NSFW.
Even SFW images can be mistakenly classified as NSFW by the NSFW_HIGH_RECALL classifier and it'll trigger the user label.
I've dug into the open-sourced X algorithm code and found their logic for user NSFW labels (which affect search deboosting and such).
Here's the logic that applies NSFW user labels (the ones which prevent you from being shown in search, timelines, etc)
About 1-2 years ago, I designed and built a SiC membrane based ultrafiltration system for a private swimming pool (~36 m3).
The tech for the pool was in a hard-to-access subbasement with limited height, so a properly designed deep bed filter wouldn't fit. Polymer ultrafiltration is rather fragile and conventional ceramic membranes (alumina, zirconia, etc.) aren't much better.
After research and cost comparisons, I've decided to use SiC membranes, which do not degrade even under harsh chemical cleaning and have a lower fouling tendency than other materials.
Filtration performance is very hard to predict, so I ran some preliminary tests (silt density index, water quality, etc.) and picked a suitable membrane area based off that. This amounted to about 9 m2 of membrane area.
I found a suitable membrane manufacturer in CN and ordered the membranes and housing from them. You can see them in the 3rd photo. Cost was about $5k including shipping via air freight.
Since the pool had low loading, I opted to backwash using the pool water, which removed the need for filtrate storage or a 3-housing setup. Provisions to install flocculation and charcoal dosing were made, but performance was satisfactory without either. The physical layout allows me to add 2 more housings if it became necessary without significant changes to the piping.
The resulting water quality is extremely good, even with the less-than-ideal hydraulics of the pool. The 4th picture shows the pool water after a year of operation.
Post about the controls follows.
1
2
184
Controls used the existing Siemens S7-1500 PLC (1st pic) and G120X VFD (3rd pic) that I installed a long time ago. Photo was from a work-in-progress, so it's not yet labelled or organized.
Pump is closed-loop controlled to ensure constant-flow conditions. Flow meter is just above the pump in the second pic. Pressure transmitters ensure that the operational envelope of the membranes isn't exceeded.
Heating is performed via a heat exchanger and a controllable pump. This uses a cascaded PI controller--slow loop on the filter inlet water temperature that controls the fast loop, fast loop on the HX outlet water temperature that controls the pump.
Regular and chemically enhanced backwash are performed fully automatically. Data is logged into a time-series DB for monitoring.
Bleach and acid dosing are performed closed-loop via a pH/ORP electrode as well. Diagnostic data (reference/glass impedance) are used as maintenance indicators. I decided to not use a free Cl2 sensor in this case, but it'd be a more reliable metric than ORP.
Due to the narrow pH range of the medium, a standard PI controller was good enough under all operating conditions.